Important: The drier bottle contains "Gel", an extremely
hygroscopic (water-absorbing) substance. At normal humidity
a drier bottel left open will become useless within
20 minutes. After having taken off the refrigerant hoses seal
drier bottle immediately by means of sealing plugs. L
Open pressure valve on compressor.
Let out refrigerant.
Important: Note safety measures.
Note when assembling: Emptying and filling of air conditioning
system cf. 64 50 009.
Screw off refrigerant hoses.
Take off drier bottle.
Note when assembling:
(a) Fit filter into drier bottel outlet.
(b) Apply a coating of refrigerant onto threads.
(c) Use copper sealing rings only once.


Siehe auch 64 50 009
53010001 - click to zoom