Open the pressure valve on the compressor.
Drain the coolant.
Warning: Observe safety precautions.
When installing: Evacuate and refill the system
(64 50 009).
Unscrew the coolant lines.
When installing:
a) Coat threads with low temperature resistant oil.
b) Do not re-use copper sealing rings.
Warning: Plug the coolant lines immediately after
disconnecting, to prevent moisture from entering the
dehumidifier and rendering it inoperative.



Siehe auch 64 50 009
52020001 - click to zoom
 
Loosen the screws on the swivel plate.
Take off the V-belt.
Unscrew the compressor from the swivel plate.
Break the electrical connections.
Remove the compressor downwards.

52020002 - click to zoom