Loosen screw (2). Pull off reversing light cable. When installing: After loosening screw (1) and (2), adjust position of transmission switch until the correct light is illuminated on the scale in the instrument housing when the selector lever is fully engaged. Warning: Supply lines to transmission switch are electrically live. Transmission switch is on positive (+) side of circuit.
|