- converter housing removed - Detach primary pump at converter housing. | ![]() |
Remove primary pump. Note when fitting: Check oil seal (1), replacing if necessary. | ![]() |
Check radial play¹ between the driven gear and the pump housing. The gear must turn 360° for this purpose. ¹ See specifications
| ![]() |
Check axial play¹ of both gears to the face surface. (Use feeler gauge or dial gauge.) ¹ See specifications
| ![]() |
Installation distance need only be observed if needle bearing was replaced. Distance A of 1.7 mm (0.067") from face of needle bearing to drive end face of pump gear. | ![]() |
The annular groove in the pump gear face the converter housing. The oil return bore in the primary pump housing must be aligned with the return bore in the converter housing. | ![]() |
Check if primary pump round freely and smoothly with operating flange 7054. | ![]() |


¹ See specifications