A) Version with pressure sensor
Remove control unit - 13 61 000.
Connect tester EFAW 228 to harness plug.
Do not connect control unit.
Set switch A at measuring position .
Set switch B at temperature sensor position.
Turn on ignition.
Reference values at air temperature ¹ - Gauge reading
- 10º C/ + 14º F 9.6 ± 10%
0º C/ + 32º F 6.4 ± 10%
+10º C/ + 50º F 4.3 ± 10%
+20º C/ + 68º F 3.0 ± 10%
+30º C/ + 86º F 2.1 ± 10%
+40º C/ + 104º F 1.5 ± 10%
+50º C/ + 122º F 1.0 ± 10%
+60º C/ + 140º F 0.79 ± 10%

¹ Temperature sensor removed


Siehe auch 13 61 000
62509001 - click to zoom
 
B9 Version with air flow sensor
Connect tester, Bosch No. 0 684 100 202.
For reference values see function test - 13 60 009.


Siehe auch 13 60 009
62509002 - click to zoom