Loosen the threaded union (1). Take out the coil spring (2) and piston (3). Warning: The relaxed spring length¹) must not be altered. Take ff the oil pump cover (4). ¹ See technical data
| ![]() |
Check clearance¹) between the outer rotor and the pump body. If the maximum permitted clearance has been exceeded, replace the pump body. ¹) See technical data
| ![]() |
Check the gap¹) between the inner and outer rotors. I the maximum permitted gap has been exceeded, replace outer and inner rotors. ¹) See technical data
| ![]() |
Check clearance¹) between the rotor sealing face and the pump housing. If the maximum permitted clearance has been exceeded, replace the pump housing. ¹) See technical data
| ![]() |
Pull off the outward flange with an extractor, do not force or lever off. | ![]() |
When installing: The distance from the flange o the inner rotor A = 44,3 ± 0,1 mm (1.744 ± 0.004 in.). | ![]() |
Warning: Vent drilling must be carefully cleaned. Oil pumps without vent drilling cannot be subsequently provided with such a drilling. | ![]() |
Ventilation of pressure chamber (D) at commencement of feed is effected via drilling (E) being controlled by the pressure relief piston. Hereby the lighting-up period of the oil pressure telltale is considerably shortened. | ![]() |
¹ See technical data