Loosen the threaded union (1).
Take out the coil spring (2) and piston (3).
Warning: The relaxed spring length¹) must not be altered.
Take ff the oil pump cover (4).


Siehe auch ¹ See technical data
41512001 - click to zoom
 
Check clearance¹) between the outer rotor and the pump body.
If the maximum permitted clearance has been exceeded,
replace the pump body.


Siehe auch ¹) See technical data
41512002 - click to zoom
 
Check the gap¹) between the inner and outer rotors. I the
maximum permitted gap has been exceeded, replace outer and
inner rotors.


Siehe auch ¹) See technical data
41512003 - click to zoom
 
Check clearance¹) between the rotor sealing face and the
pump housing.
If the maximum permitted clearance has been exceeded, replace
the pump housing.


Siehe auch ¹) See technical data
41512004 - click to zoom
 
Pull off the outward flange with an extractor, do not force
or lever off.

41512005 - click to zoom
 
When installing: The distance from the flange o the inner
rotor A = 44,3 ± 0,1 mm (1.744 ± 0.004 in.).

41512006 - click to zoom
 
Warning: Vent drilling must be carefully cleaned.
Oil pumps without vent drilling cannot be subsequently
provided with such a drilling.

41512007 - click to zoom
 
Ventilation of pressure chamber (D) at commencement of
feed is effected via drilling (E) being controlled by the pressure
relief piston.
Hereby the lighting-up period of the oil pressure telltale is
considerably shortened.

41512008 - click to zoom