Connecting rods with re-machined small end bushes are
available as spare parts.
Press out the old small end bush.
When installing: Press in the new bush with the gap at
90° to the oil drillway.


24601001 - click to zoom
 
Open out, clean and beburr the oil drillways.
Ream out the small end bush¹.
The gudgeon pin must pass through the small end bush if
light pressure is exerted.
¹ For gudgeon pin running clearances, see technical data.


Siehe auch ¹ See technical data
24601002 - click to zoom
 
Check connecting rods for deviation from parallel (A)
and maximum permitted distortion (B) and align if necessary.
A 150 - 0.04 mm (5.9055 - 0.0016 in)
B 0° - 30'

24601003 - click to zoom
 
Cross-section through cylinder

24601004 - click to zoom